Tag Archives: commercial ice cream freezer

Commercial Ice Maker Repair: All About Ice Maker Problems

ice cream freezer repair

When you purchase the ice cream freezer, you want to your clients to always get the ice cream when they need it. Unfortunately, this isn’t always the case as the unit tends to stop working from time to time. It can sometimes stop making ice cream. In other cases, it might make ice cream that isn’t cold enough.

Reason why your unit doesn’t work

According to commercial ice maker repair professionals, there are plenty of reasons why your unit might fail to work as effectively as you would want it to. Some of the common reasons include:

Dirty coils: When is the last time you cleaned the coils? If your unit isn’t working, look behind the refrigerator and take a look at the coils. Are they dirty? That might be the reason for the problem.

Frost: Other than dust, the coils might be having plenty of frost on them. When inspecting for dust, also inspect for frost. If present, get rid of it as soon as possible.

  1. Use of the freezer: How are you using the freezer? Do you open it and leave it open for long periods? This might be the reason why you aren’t getting ice cream that is cold enough.

Ineffective door seals: You might be thinking that your unit is faulty or has a complex problem and yet the problem is as simple as fixing the door seals. Commercial appliances repair experts recommend that you place your hand along the edges of the closed door. If you feel any cool air, plenty of air is getting lost and this might be the cause of the problem.

What to do about the problem

All you need to do is simple—fix the problem. If the coils are dirty, clean them. You can clean them on your own or hire a contractor to help you out. In some cases, you might find that the problem is due to frost build up. For your unit to resume top-notch performance you need to defrost the unit.

You should note that you have to remove all the things from the freezer before you do the defrosting. The process is usually time consuming and messy. If you aren’t up to the challenge, hire a commercial kitchen appliance repairs professional to help you out.

Conclusion

These are some of the common reasons why your ice cream freezer isn’t making the ice cream that you want. If the problems are more than you can handle, don’t spoil your unit—let an experienced ice cream freezer repair Arington to handle it.

Ice Cream Freezer Repair: Taking A Look At The Common Ice cream Freezer Problems And How To Diagnose Them

ice cream freezer repair

Just like any other electrical appliances, commercial ice cream freezers are exposed to some common failures during their lifetime. It might be an electrical failure or just a simple fan detachment. We are going to look at some of the common problems, causes and ice cream freezer repair methods you can implement to have a fully functioning freezer in no time.

Freezing and cooling System issues

The most common cause of the cooling system failure is the presence of leakages in the compressor coil or thermostat miss configuration. To resolve this, check and see if the thermostat is configured correctly. If not, you should adjust the temperature knob to the required level.

Power issues

Power issues with your ice cream freezer are mostly caused by a non-functioning fuse, overheated power supply unit or just a power surge in your main line. To solve this, you should ensure that the freezer is turned off for safety reasons and check the power source to confirm whether there is any fault with the circuit breaker. Confirm if the fuse you use is firmly connected to the plug. If there are no faults, contact a commercial appliances repair professional to check the whole system.

Compressor issues

The compressor will stop to function if there is a defective coil running through the system and if there is a sudden change in room temperature where your ice cream freezer is positioned, and if there is an ice clog in the compressor coils. If the compressor is not functioning well, you should reset the temperature of the freezer to its normal set-point for a few hours and monitor its behavior. If this does not work, shut down the system completely for up to 12 hours particularly if it had been running for an extended period and check to see if the issue has been resolved.

Condenser fan complications

The condenser fan can suddenly start to rotate at an extremely fast rate or an unquestionably slow speed producing some noise. The prevalent cause of this is the occurrence of a loose bolt or just a lubrication issue with the rotating screw. You should shut the whole system off and unscrew the fan from the freezer. Using a lubrication agent, you should oil the rotating screw and clean the back of the fan box to remove potential threats.

Conclusion

These are some of the most common problems with ice cream freezers. When you come across a problem that you can’t easily fix, you should contact and experienced commercial freezer repair Arlington to help you in fixing it.